Skip to content
Open access · CC-BY via OpenAlex

Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence

Raghad S. Alsharidah, Razique Anwer, Maysoon A. Abdelhamid, Eman Amer Alanazi, Farah Mfwadh Alanazi, Haneen Fahaid Alanazi, Jumanah Naif Alotaibi, Lama Abdulaziz Alshathri, Renad Ali Alshehri, Rania Alsuhibani, Raghad Hassan Majrashi

Biosensors · 2026

Abstract

Background: Wearable sweat biosensors have emerged as a promising non-invasive approach for monitoring inflammatory biomarkers, offering an alternative to repeated blood sampling. This systematic review evaluated the current evidence on the detection of C-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) in sweat for infection and inflammatory disease monitoring. Methods: Following PRISMA 2020 guidelines (PROSPERO: CRD420261371221), PubMed/MEDLINE, Scopus, Web of Science, IEEE Xplore, and Google Scholar were searched through April 2026. Human studies measuring CRP, IL-6, or TNF-α in sweat using wearable or biosensor-based platforms were included. Risk of bias and certainty of evidence were assessed using a modified Newcastle–Ottawa Scale/JBI checklist and GRADE. Results: Thirteen studies (2020–2025, 5–80 participants) were included. CRP showed the most consistent sweat-serum agreement (r = 0.844) and good diagnostic performance in one inflammatory bowel disease cohort (AUC = 0.845). TNF-α demonstrated the highest diagnostic accuracy in a single longitudinal study (AUC = 0.962), whereas IL-6 showed moderate sweat-serum correlations (R2 = 0.60–0.72) but limited diagnostic discrimination. IL-6 and TNF-α were more consistently detected in passively collected eccrine sweat, although IL-6 was also successfully measured following pilocarpine iontophoresis in one study. Most studies had moderate methodological quality. Conclusions: Sweat-based measurement of CRP, IL-6, and TNF-α is analytically feasible for non-invasive inflammatory biomarker monitoring. However, current evidence remains limited by small, heterogeneous studies, underscoring the need for standardized protocols and larger prospective clinical validation.

◌ CITATION ONLY
Full text is not openly licensed for redistribution here. Read it at the source:

Read at source →

Provenance

Source
OpenAlex
DOI
10.3390/bios16090521
Canonical
link ↗
Fetched
2026-11-13 MST

Cite this

APA
Alsharidah, R.S., Anwer, R., Abdelhamid, M.A., Alanazi, E.A., Alanazi, F.M., Alanazi, H.F., Alotaibi, J.N., Alshathri, L.A., Alshehri, R.A., Alsuhibani, R., &amp; Majrashi, R.H. (2026). Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence. <em>Biosensors</em>. https://doi.org/10.3390/bios16090521
Vancouver
Alsharidah RS, Anwer R, Abdelhamid MA, Alanazi EA, Alanazi FM, Alanazi HF, et al. Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence. Biosensors. 2026. doi:10.3390/bios16090521.
BibTeX
@article{raghad2026Wearab, title = {Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence}, author = {Raghad S. Alsharidah and Razique Anwer and Maysoon A. Abdelhamid and Eman Amer Alanazi and Farah Mfwadh Alanazi and Haneen Fahaid Alanazi and Jumanah Naif Alotaibi and Lama Abdulaziz Alshathri and Renad Ali Alshehri and Rania Alsuhibani and Raghad Hassan Majrashi}, journal = {Biosensors}, year = {2026}, doi = {10.3390/bios16090521}, }

Research neighborhood

References, citing works, and semantically nearest findings. Click a node to open it.

Related findings