Skip to content
Open access · OA via Europe PMC

Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence.

Alsharidah RS, Anwer R, Abdelhamid MA, Alanazi EA, Alanazi FM, Alanazi HF, Alotaibi JN, Alshathri LA, Alshehri RA, Alsuhibani R, Majrashi RH.

Biosensors · 2026

Abstract

<i>Background</i>: Wearable sweat biosensors have emerged as a promising non-invasive approach for monitoring inflammatory biomarkers, offering an alternative to repeated blood sampling. This systematic review evaluated the current evidence on the detection of C-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) in sweat for infection and inflammatory disease monitoring. <i>Methods</i>: Following PRISMA 2020 guidelines (PROSPERO: CRD420261371221), PubMed/MEDLINE, Scopus, Web of Science, IEEE Xplore, and Google Scholar were searched through April 2026. Human studies measuring CRP, IL-6, or TNF-α in sweat using wearable or biosensor-based platforms were included. Risk of bias and certainty of evidence were assessed using a modified Newcastle-Ottawa Scale/JBI checklist and GRADE. <i>Results</i>: Thirteen studies (2020-2025, 5-80 participants) were included. CRP showed the most consistent sweat-serum agreement (r = 0.844) and good diagnostic performance in one inflammatory bowel disease cohort (AUC = 0.845). TNF-α demonstrated the highest diagnostic accuracy in a single longitudinal study (AUC = 0.962), whereas IL-6 showed moderate sweat-serum correlations (R<sup>2</sup> = 0.60-0.72) but limited diagnostic discrimination. IL-6 and TNF-α were more consistently detected in passively collected eccrine sweat, although IL-6 was also successfully measured following pilocarpine iontophoresis in one study. Most studies had moderate methodological quality. <i>Conclusions</i>: Sweat-based measurement of CRP, IL-6, and TNF-α is analytically feasible for non-invasive inflammatory biomarker monitoring. However, current evidence remains limited by small, heterogeneous studies, underscoring the need for standardized protocols and larger prospective clinical validation.

◌ CITATION ONLY
Full text is not openly licensed for redistribution here. Read it at the source:

Read at source →

Provenance

Source
Europe PMC
DOI
10.3390/bios16090521
Canonical
link ↗
Fetched
2026-10-09 MST

Cite this

APA
RS, A., R, A., MA, A., EA, A., FM, A., HF, A., JN, A., LA, A., RA, A., R, A., &amp; RH., M. (2026). Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence. <em>Biosensors</em>. https://doi.org/10.3390/bios16090521
Vancouver
RS A, R A, MA A, EA A, FM A, HF A, et al. Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence. Biosensors. 2026. doi:10.3390/bios16090521.
BibTeX
@article{alsharidah2026Wearab, title = {Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence.}, author = {Alsharidah RS and Anwer R and Abdelhamid MA and Alanazi EA and Alanazi FM and Alanazi HF and Alotaibi JN and Alshathri LA and Alshehri RA and Alsuhibani R and Majrashi RH.}, journal = {Biosensors}, year = {2026}, doi = {10.3390/bios16090521}, }

Research neighborhood

References, citing works, and semantically nearest findings. Click a node to open it.

Related findings