Open access · CC-BY
via OpenAlex
Development and Validation of a Robust and Straightforward LC-MS Method for Measuring Taurine in Whole Blood and Plasma of Dogs and Reference Intervals Calculation
Tommaso Furlanello, Riccardo Masti, Francesca Maria Bertolini, Valeria Ongaro, Andrea Zoia, José Sánchez del Pulgar
Animals · 2024 · ▲ 3 citations
Abstract
Several studies have highlighted the essential role of taurine in maintaining the health of small animals, particularly dogs. Taurine deficiency has been linked to various health issues, especially in certain dog breeds. Therefore, accurately assessing taurine levels in canine blood is crucial for diagnosing and monitoring these conditions. In this study, we present the development of a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for rapidly quantifying taurine concentrations in dog whole blood and plasma. The method was validated according to current guidelines, showing excellent accuracy, precision, and sensitivity across a wide concentration range. Specifically, the limit of quantification was set at 80 nmol/mL for whole blood and 8 nmol/mL for plasma, ensuring the method's reliability for both matrices. The application of this validated technique to blood samples of healthy dogs allowed for the establishment of reference intervals for taurine concentrations (148 to 495 nmol/mL for whole blood; 42 to 183 nmol/mL for plasma). Due to its robustness and simplicity, this method represents a valuable tool, supporting its routine use in health assessments and enabling more effective monitoring of taurine status in dogs.
◌ CITATION ONLY
Full text is not openly licensed for redistribution here. Read it at the source:
Provenance
- Source
- OpenAlex
- DOI
- 10.3390/ani15010003
- Canonical
- link ↗
- Fetched
- 2026-10-11 MST
Cite this
APA
Furlanello, T., Masti, R., Bertolini, F.M., Ongaro, V., Zoia, A., & Pulgar, J.S.D. (2024). Development and Validation of a Robust and Straightforward LC-MS Method for Measuring Taurine in Whole Blood and Plasma of Dogs and Reference Intervals Calculation. <em>Animals</em>. https://doi.org/10.3390/ani15010003
Vancouver
Furlanello T, Masti R, Bertolini FM, Ongaro V, Zoia A, Pulgar JSD. Development and Validation of a Robust and Straightforward LC-MS Method for Measuring Taurine in Whole Blood and Plasma of Dogs and Reference Intervals Calculation. Animals. 2024. doi:10.3390/ani15010003.
BibTeX
@article{tommaso2024Develo,
title = {Development and Validation of a Robust and Straightforward LC-MS Method for Measuring Taurine in Whole Blood and Plasma of Dogs and Reference Intervals Calculation},
author = {Tommaso Furlanello and Riccardo Masti and Francesca Maria Bertolini and Valeria Ongaro and Andrea Zoia and José Sánchez del Pulgar},
journal = {Animals},
year = {2024},
doi = {10.3390/ani15010003},
}
Research neighborhood
References, citing works, and semantically nearest findings. Click a node to open it.
Related findings
Journal of Korean Medical Science 2014
Open access · CC-BY
New Reference Data on Bone Mineral Density and the Prevalence of Osteoporosis in Korean Adults Aged 50 Years or Older: The Korea National Health and Nutrition Examination Survey 2008-2010
Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease 2014
Open access · OA
The molecular targets of resveratrol
EFSA Supporting Publications 2026
Open access · OA
Technical Assistance on the safety of taurine for dogs
PLoS ONE 2023
Open access · CC-BY
Correction: Development of plasma and whole blood taurine reference ranges and identification of dietary features associated with taurine deficiency and dilated cardiomyopathy in golden retrievers: a prospective, observational study
AJOG Global Reports 2023
Open access · CC-BY
Comparative predictive power of serum vs plasma proteomic signatures in feto-maternal medicine
Biological Psychiatry 2023
Open access · CC-BY