Skip to content
Citation only via OpenAlex

Bone Density Measurements of Osteoporosis in the Aged

Jacob Gershon-Cohen, Harald Schraer, Nathan Blumberg

Radiology · 1955 · ▲ 21 citations

Abstract

Osteoporosis as diagnosed by the roentgenologist lacks the objectivity necessary for accuracy (1). Many physical aids have been suggested (2–6), but those of the Pennsylvania State University physicists (7–9), by which quantitative estimates of bone density may be obtained with the use of densitometric and computation equipment, seemed to us to be the most advanced. With their collaboration, the roentgenographic evaluation of osteoporosis was undertaken in a group of aged persons, and the preliminary findings are here reported. The densitometer used has been specially modified for this purpose. The computers consist of a function transformer and recording, integrating, and counting devices. Methods Skeletal x-ray examinations were made of 149 healthy ambulatory residents in the Home for the Jewish Aged in Philadelphia. This group comprised 52 men and 97 women ranging from sixty-three to ninety-eight years of age. The densitometric analyses were made from non-screen x-ray films of the left hand and foot of each subject. An aluminum-zinc alloy wedge was simultaneously exposed after being placed on the film, with a constant film-target distance of 40 inches (Fig. 1). For measuring the thickness of the soft tissues over the os calcis, a narrow strip of lead 1/16 inch thick was wrapped around the posterior aspect of the heel. The bone density coefficients were then calculated by the physicist group and later compared with our roentgenographic clinical appraisal of osteoporosis. The figures supplied by the physicists were reported as an average “density coefficient” for the particular cross-sectional slice of bone evaluated, indicated by the etched lines in Figure 1. This density coefficient can be multiplied by a constant factor denning the density of the bone in grams of bone ash per cubic centimeter of bone. This conversion factor is approximately 0.32, but its exact value must await additional experimental work. In the meantime our results are reported merely in terms of “density coefficient.” In the case of soft tissues, this coefficient is simply a measure of the relative x-ray absorbing power of the tissues and has no known relationship to their density. Results Study of the frequency distribution of density coefficients indicated that the women of this group had bones of lesser density than the men. Most of the women showed a density coefficient between 0.55 and 0.59 for the os calcis, while that of the men fell between 0.60 and 0.64. Worthy of note perhaps is the narrow peak for the women and the broader peak for the men (Fig. 2). Frequency distribution curves of density coefficients obtained through the middle phalanx of the left fifth finger showed more variation among the women than among the men, when measured through the midshaft ; but when measurements were made through the metaphyses, the coefficient curves resembled those of the os calcis (Figs. 3 and 4).

◌ CITATION ONLY
Full text is not openly licensed for redistribution here. Read it at the source:

Read at source →

Provenance

Source
OpenAlex
DOI
10.1148/65.3.416
Canonical
link ↗
Fetched
2026-10-18 MST

Cite this

APA
Gershon-Cohen, J., Schraer, H., &amp; Blumberg, N. (1955). Bone Density Measurements of Osteoporosis in the Aged. <em>Radiology</em>. https://doi.org/10.1148/65.3.416
Vancouver
Gershon-Cohen J, Schraer H, Blumberg N. Bone Density Measurements of Osteoporosis in the Aged. Radiology. 1955. doi:10.1148/65.3.416.
BibTeX
@article{jacob1955BoneDe, title = {Bone Density Measurements of Osteoporosis in the Aged}, author = {Jacob Gershon-Cohen and Harald Schraer and Nathan Blumberg}, journal = {Radiology}, year = {1955}, doi = {10.1148/65.3.416}, }

Research neighborhood

References, citing works, and semantically nearest findings. Click a node to open it.

Related findings