Preprint · CC-BY
via bioRxiv
Alpha-180 spin-echo based line-scanning method for high resolution laminar-specific fMRI
Choi, S., Hike, D., Pohmann, R., Avdievich, N. I., Cid, L. G., Man, W., Scheffler, K., Yu, X.
biorxiv · 2024
Abstract
Laminar-specific functional magnetic resonance imaging (fMRI) has been widely used to study circuit-specific neuronal activity by mapping spatiotemporal fMRI response patterns across cortical layers. Hemodynamic responses reflect indirect neuronal activity given limit of spatial and temporal resolution. Previous gradient-echo based line-scanning fMRI (GELINE) method was proposed with high temporal (50 ms) and spatial (50 {micro}m) resolution to better characterize the fMRI onset time across cortical layers by employing 2 saturation RF pulses. However, the imperfect RF saturation performance led to poor boundary definition of the reduced region of interest (ROI) and aliasing problems outside of the ROI. Here, we propose (alpha)-180 spin-echo-based line-scanning fMRI (SELINE) method to resolve this issue by employing a refocusing 180{degrees} RF pulse perpendicular to the excitation slice. In contrast to GELINE signals peaked at the superficial layer, we detected varied peaks of laminar-specific BOLD signals across deeper cortical layers with the SELINE method, indicating the well-defined exclusion of the large drain-vein effect with the spin-echo sequence. Furthermore, we applied the SELINE method with 200 ms TR to sample the fast hemodynamic changes across cortical layers with a less draining vein effect. In summary, this SELINE method provides a novel acquisition scheme to identify microvascular-sensitive laminar-specific BOLD responses across cortical depth.
◌ CITATION ONLY
Full text is not openly licensed for redistribution here. Read it at the source:
Provenance
- Source
- bioRxiv
- DOI
- 10.1101/2023.05.09.540065
- Canonical
- link ↗
- Fetched
- 2026-05-31 MST
Cite this
APA
S., C., D., H., R., P., I., A.N., G., C.L., W., M., K., S., & X., Y. (2024). Alpha-180 spin-echo based line-scanning method for high resolution laminar-specific fMRI. <em>biorxiv</em>. https://doi.org/10.1101/2023.05.09.540065
Vancouver
S. C, D. H, R. P, I. AN, G. CL, W. M, et al. Alpha-180 spin-echo based line-scanning method for high resolution laminar-specific fMRI. biorxiv. 2024. doi:10.1101/2023.05.09.540065.
BibTeX
@unpublished{choi2024Alphas,
title = {Alpha-180 spin-echo based line-scanning method for high resolution laminar-specific fMRI},
author = {Choi, S. and Hike, D. and Pohmann, R. and Avdievich, N. I. and Cid, L. G. and Man, W. and Scheffler, K. and Yu, X.},
journal = {biorxiv},
year = {2024},
doi = {10.1101/2023.05.09.540065},
}
Research neighborhood
References, citing works, and semantically nearest findings. Click a node to open it.
Related findings
biorxiv 2024
Preprint · CC-BY
NeuroCSF: an fMRI method to measure contrast sensitivity function in human visual cortex
biorxiv 2024
Preprint · CC-BY
Improved Temporal and Spatial Focality of Non-invasive Deep-brain Stimulation using Multipolar Single-pulse Temporal Interference with Applications in Epilepsy
American Journal of Dermatopathology 2003
Citation only
The Longer Your Telomeres, the Larger Your Nevus?
Evolution 1957
Citation only
Pleiotropy, Natural Selection, and the Evolution of Senescence
biorxiv 2024
Preprint · CC-BY
Neonatal Amygdala Mean Diffusivity: A Potential Predictor of Emotional Face Perception
biorxiv 2024
Preprint · CC-BY