Skip to content
Open access · CC-BY via OpenAlex

A new age-related cutoff of medial temporal atrophy scale on MRI improving the diagnostic accuracy of neurodegeneration due to Alzheimer’s disease in a Chinese population

Mingqing Wei, Jing Shi, Jingnian Ni, Xuekai Zhang, Ting Li, Zilong Chen, Mengling Zhou, Liping Zhang, Zhongjian Tan, Yongyan Wang, Jinzhou Tian

BMC Geriatrics · 2019 · ▲ 34 citations

Abstract

BACKGROUND: Visual rating scales are still the most popular tools in assessing atrophy degrees of whole brain and lobes. However, the false negative rate of the previous cutoff score of visual rating scales was relatively high for detecting dementia of Alzheimer's type (DAT). This study aimed to evaluate the diagnostic value of new cutoffs of visual rating scales on magnetic resonance imaging for discriminating DAT in a Chinese population. METHODS: Out of 585 enrolled subjects, 296 participants were included and diagnosed as normal cognition (NC)(n = 87), 138 diagnosed as amnestic mild cognitive impairment (aMCI), and 71 as dementia of Alzheimer's type (DAT). Receiver operating characteristic (ROC) curve analyses were used to calculate the diagnostic value of visual rating sales (including medial temporal atrophy (MTA), posterior atrophy rating scale (PA),global cortical atrophy scale (GCA) and medial temporal-lobe atrophy index (MTAi))for detecting NC from DAT . RESULTS: Scores of MTA correlated to age and Mini-mental state examination score. When used to detect DAT from NC, the MTA showed highest diagnostic value than other scales, and when the cutoff score of 1.5 of MTA scale, it obtained an optimal sensitivity (84.5%) and specificity (79.1%) respectively, with a 15.5% of false negative rate. Cutoff scores and diagnostic values were calculated stratified by age. For the age ranges 50-64, 65-74, 75-84 years, the following cut-offs of MTA should be used, ≥1.0(sensitivity and specificity were 92.3 and 68.4%), ≥1.5(sensitivity and specificity were 90.4 and 85.2%), ≥ 2.0(sensitivity and specificity were 70.8 and 82.3%) respectively. All of the scales showed relatively lower diagnostic values for discriminating aMCI from NC. CONCLUSIONS: The new age-based MTA cutoff showed better diagnostic accuracy for detecting DAT than previous standard, the list of practical cut-offs proposed here might be useful in clinical practice.

◌ CITATION ONLY
Full text is not openly licensed for redistribution here. Read it at the source:

Read at source →

Provenance

Source
OpenAlex
DOI
10.1186/s12877-019-1072-8
Canonical
link ↗
Fetched
2026-10-27 MST

Cite this

APA
Wei, M., Shi, J., Ni, J., Zhang, X., Li, T., Chen, Z., Zhou, M., Zhang, L., Tan, Z., Wang, Y., &amp; Tian, J. (2019). A new age-related cutoff of medial temporal atrophy scale on MRI improving the diagnostic accuracy of neurodegeneration due to Alzheimer’s disease in a Chinese population. <em>BMC Geriatrics</em>. https://doi.org/10.1186/s12877-019-1072-8
Vancouver
Wei M, Shi J, Ni J, Zhang X, Li T, Chen Z, et al. A new age-related cutoff of medial temporal atrophy scale on MRI improving the diagnostic accuracy of neurodegeneration due to Alzheimer’s disease in a Chinese population. BMC Geriatrics. 2019. doi:10.1186/s12877-019-1072-8.
BibTeX
@article{mingqing2019Anewag, title = {A new age-related cutoff of medial temporal atrophy scale on MRI improving the diagnostic accuracy of neurodegeneration due to Alzheimer’s disease in a Chinese population}, author = {Mingqing Wei and Jing Shi and Jingnian Ni and Xuekai Zhang and Ting Li and Zilong Chen and Mengling Zhou and Liping Zhang and Zhongjian Tan and Yongyan Wang and Jinzhou Tian}, journal = {BMC Geriatrics}, year = {2019}, doi = {10.1186/s12877-019-1072-8}, }

Research neighborhood

References, citing works, and semantically nearest findings. Click a node to open it.

Related findings