Skip to content
Preprint · CC-BY via bioRxiv

Longevity of Implantable Silicon-ICs for Emerging Neural Applications: Evaluation of Bare Die and PDMS-Coated ICs After Accelerated Aging and Implantation Studies

Nanbakhsh, K., Idil, A. S., Lamont, C., Ducso, C., Akgun, O. C., Horvath, D., Toth, K., Ulbert, I., Mazza, F., Constandinou, T., Serdijn, W. A., Vanhoestenberghe, A., Donaldson, N., Giagka, V.

biorxiv · 2024

Abstract

Silicon integrated circuits (ICs) are central to the next-generation miniature active neural implants, whether packaged in soft polymers for flexible bioelectronics or implanted as bare die for neural probes. These emerging applications bring the IC closer to the corrosive body environment, raising reliability concerns, particularly for long-term clinical use. Here, we evaluated the long-term electrical and material stability of silicon-ICs from two foundries, after one-year accelerated in vitro and in vivo animal studies. The ICs featured various custom-designed test structures and were partially PDMS coated, creating two regions on each chip, uncoated "bare die" and "PDMS-coated". During the accelerated in vitro study, ICs were electrically biased and periodically monitored. Results demonstrated stable electrical performance for at least a year, suggesting that bare die ICs can function in the body for months. Despite electrical stability, material analysis revealed chemical and electrically driven degradation of the IC passivation in the bare die regions. In contrast, PDMS-coated regions revealed no such degradation, making PDMS a highly suitable encapsulant for ICs intended for years-long implantation. Based on the new insights, guidelines are proposed that may enhance the longevity of implantable ICs, significantly broadening their applications in the biomedical field.

◌ CITATION ONLY
Full text is not openly licensed for redistribution here. Read it at the source:

Read at source →

Provenance

Source
bioRxiv
DOI
10.1101/2024.03.06.583769
Canonical
link ↗
Fetched
2026-10-12 MST

Cite this

APA
K., N., S., I.A., C., L., C., D., C., A.O., D., H., K., T., I., U., F., M., T., C., A., S.W., A., V., N., D., &amp; V., G. (2024). Longevity of Implantable Silicon-ICs for Emerging Neural Applications: Evaluation of Bare Die and PDMS-Coated ICs After Accelerated Aging and Implantation Studies. <em>biorxiv</em>. https://doi.org/10.1101/2024.03.06.583769
Vancouver
K. N, S. IA, C. L, C. D, C. AO, D. H, et al. Longevity of Implantable Silicon-ICs for Emerging Neural Applications: Evaluation of Bare Die and PDMS-Coated ICs After Accelerated Aging and Implantation Studies. biorxiv. 2024. doi:10.1101/2024.03.06.583769.
BibTeX
@unpublished{nanbakhsh2024Longev, title = {Longevity of Implantable Silicon-ICs for Emerging Neural Applications: Evaluation of Bare Die and PDMS-Coated ICs After Accelerated Aging and Implantation Studies}, author = {Nanbakhsh, K. and Idil, A. S. and Lamont, C. and Ducso, C. and Akgun, O. C. and Horvath, D. and Toth, K. and Ulbert, I. and Mazza, F. and Constandinou, T. and Serdijn, W. A. and Vanhoestenberghe, A. and Donaldson, N. and Giagka, V.}, journal = {biorxiv}, year = {2024}, doi = {10.1101/2024.03.06.583769}, }

Research neighborhood

References, citing works, and semantically nearest findings. Click a node to open it.

Related findings